{"product_id":"stc-3000-ac-110v-220v-12v-24v-digital-temperature-controller-thermostat-thermoregulator-incubator-thermometer-sensor-heating-cooling","title":"STC-3000 AC 110V-220V\/12V\/24V Digital Temperature Controller Thermostat Thermoregulator Incubator Thermometer Sensor Heating Cooling","description":"\u003cdiv\u003e\u003cspan\u003e\u003cstrong\u003eSTC-3000 AC 110V-220V Digital Temperature Controller Thermostat Thermoregulator Incubator Thermometer Sensor Heating Cooling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"detailmodule_html\"\u003e\n\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp class=\"MsoNormal\"\u003eSwitch the modes between cool and heat;\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eControl temperature by setting the temperature setting value and the difference value;\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTemperature calibration;\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRefrigerating control output delay protection;\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAlarm when temperature exceeds temperature limit or when sensor error.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSpecification\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eFront panel size: 75x34.5(mm)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMounting size: 71x29(mm)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eProduct size: 75x34.5x85(mm)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSensor length: 1 meter (include the probe)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTechnical Parameters\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eTemperature measuring range: -50~99 Celsius\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAccuracy: 0.1Celsius\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSensor error delay: 1 minute\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePower supply: DC 12V, DC 24V, 110V\/220V AC+10%, 50\/60Hz\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003ePower consumption: \u0026lt;3w\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eSensor: NTC sensor(IPC)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRelay contact capacity: Cool (10A\/220VAC); Heat (10A\/220VAC)\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eAmbient temperature: 0-60Celsius\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStorage temperature: -30-75Celsius\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eRelative humidity: 20-85%(No condensate)\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp class=\"MsoNormal\"\u003eFeature:\u003c\/p\u003e\n\u003cp class=\"p\"\u003eBe able to control temperature and humidity at the same time.\u003c\/p\u003e\n\u003cp class=\"p\"\u003eBe able to connect with humidifier and dehumidifier equipment at the same time.\u003c\/p\u003e\n\u003cp class=\"p\"\u003eBe able to connect with refrigeration\/ heating and humidifier\/dehumidifier equipment at the same time.\u003c\/p\u003e\n\u003cp class=\"p\"\u003eHeating\/Cooling function could be set separately for refrigeration and heating to protect temperature controller from violent change. Same as humidity Control.\u003c\/p\u003e\n\u003cp class=\"p\"\u003eSupporting Temp and Humidity Calibration\u003c\/p\u003e\n\u003cp class=\"p\"\u003e[Dual Display Window] Be able to display measured temperature\/humidity and set temp\/humidity at the same time\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndicator light status instruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eIndicator light\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eCool indicator light\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eOn:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eHeat indicator light\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eOn: heating starts;Off:heating stops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eSet indicator light\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eOn:parameter setting status\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003eey operation instruction\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp align=\"start\"\u003e\u003cstrong\u003e\u003cspan\u003e①\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eView parameter method: When the controller is working normally, press and release the “▲” button once, d\u003c\/span\u003e\u003cspan\u003eisplay the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds return to normal temperature display state\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cstrong\u003e\u003cspan\u003e②.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eSet the parameter method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eWhen the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eThe indicator light is on, and the digital tube displays the code \"F1\" of the first menu item.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003ePress “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eThe key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003ethe key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down \"S\" and \"▲\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eThe key or “▼” key can quickly up or down and display the parameter settings of the current menu.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eAfter the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eIf there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cstrong\u003e\u003cspan\u003e③\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eRepair system data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eWhen the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv align=\"start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e\u003cstrong\u003eOperation instruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eUnder controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off”\u003c\/span\u003e\u003cspan\u003estatus, press and hold “ ” key for 3s can turn on the controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eUnder the controller normal working status, screen displays the current temperature value; also the controller can also\u003c\/span\u003e\u003cspan\u003eswitch the working mode between heating and cooling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eController starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value +\u003c\/span\u003e\u003cspan\u003edifference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigeratingequipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eSystem starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat”\u003c\/span\u003e\u003cspan\u003eindicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e\u003cstrong\u003eMenu instruction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" align=\"start\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eCode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eSet range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eDefault\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eF1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eTemperature set value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e-50～99°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e10°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eF2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eTemperature difference setting value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e0.3～10°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e0.5°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eF3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eCompressor delay time\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e1～10 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e3 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eF4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eTemperature calibration value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e-10°～10°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eF5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e\u003cstrong\u003eFahrenheit\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\/\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCelsius switching\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eSet range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003e0\/1\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv align=\"start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e\u003cstrong\u003eError description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eAlarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the\u003c\/span\u003e\u003cspan\u003erunning status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eAlarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function\u003c\/span\u003e\u003cspan\u003ewhen the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzeralarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eSafety Regulations\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e▶\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eDanger\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e1.Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003econnections or overloading the relay.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e2.Dangers: Prohibit connecting the wire terminals without electricity cut-off.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e▶\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eWarning\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003eProhibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003estrong corrosion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e▶\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eNotice\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e①\u003c\/span\u003e\u003cspan\u003eThe power supply should conform to the voltage value indicated in the instruction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"start\"\u003e\u003cspan\u003e②\u003c\/span\u003e\u003cspan\u003eTo avoid the interference, the sensor down-lead and power wire should be kept a distance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"dinoinbox","offers":[{"title":"AC 110-220V","offer_id":46988134482074,"sku":"MH01935","price":19.99,"currency_code":"USD","in_stock":true},{"title":"DC 12V","offer_id":46988134514842,"sku":"MH01935-1","price":19.99,"currency_code":"USD","in_stock":true},{"title":"DC 24V","offer_id":46988134547610,"sku":"MH01935-2","price":19.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/8748\/7130\/files\/ScreenShot_2026-01-08_155207_495.png?v=1767859030","url":"https:\/\/www.dinoinbox.com\/products\/stc-3000-ac-110v-220v-12v-24v-digital-temperature-controller-thermostat-thermoregulator-incubator-thermometer-sensor-heating-cooling","provider":"dinoinbox","version":"1.0","type":"link"}